Test reports for our rebar from an accredited laboratory, the standards composite rebar is produced and tested to, and the guides it is designed to — for structural engineers, site supervisors and clients.

Tests

Tensile strength over 1,000 MPa

Our Ø8 and Ø10 rebar was tested by the Institute of Materials and Structures of the Faculty of Civil Engineering, University of Belgrade, in a laboratory accredited to ISO/IEC 17025.

Tensile strength test results for Adelaida doo composite rebar, April 2023
DiameterReportThree specimensAverageWeightGOST 31938-2012
Ø8 mmNo. 136/20231,018.6 – 1,056.4 MPa1,036.5 MPa0.080 kg/mrequirement met
Ø10 mmNo. 137/2023995.7 – 1,072.0 MPa1,022.0 MPa0.134 kg/mrequirement met

Ribbed rebar of type ASK was tested to GOST 31938-2012, Annex B — axial tension, April 2023. Every specimen is above 800 MPa, as the standard requires, and the average is above 1,000 MPa. For comparison: the yield strength of B500 steel is 500 MPa.

Report No. 136/2023 · April 2023 · 6 pages

Tensile strength test of composite rebar Ø8 mm

Institute of Materials and Structures, Faculty of Civil Engineering, University of Belgrade. Average 1,036.5 MPa, weight 0.080 kg/m.

Download report · 2.8 MB

Report No. 137/2023 · April 2023 · 6 pages

Tensile strength test of composite rebar Ø10 mm

Institute of Materials and Structures, Faculty of Civil Engineering, University of Belgrade. Average 1,022.0 MPa, weight 0.134 kg/m.

Download report · 2.8 MB

Standards and codes

What composite rebar is produced and designed to

As well as the GOST standards our rebar was tested to, structural engineers use the American guide ACI 440.1R and the national guides of other countries. Each one links to its publisher or the official register.

Composite rebar — requirements and test methods

Interstate GOST standards for fibre-reinforced polymer bars
DesignationTitlePublisherSource
GOST 31938-2022Fibre-reinforced polymer bars for concrete reinforcement. General specifications types, requirements and designation of bars — our rebar was tested to the 2012 editionInterstate standard, 2022Publisher (RST) — purchase
GOST 32492-2024… Methods for determining physical and mechanical properties replaced GOST 32492-2015Interstate standard, 2024Publisher (RST) — purchase
GOST 32486-2021… Methods for determining structural characteristics replaced GOST 32486-2015Interstate standard, 2021Publisher (RST) — purchase
GOST 32487-2015… Methods for determining resistance to aggressive mediaInterstate standard, 2016 editionPublisher (RST) — purchase

Design of concrete structures

Rules and recommendations for designing concrete structures with composite reinforcement
DesignationTitlePublisherSource
ACI 440.1R-15Guide for the Design and Construction of Structural Concrete Reinforced with Fiber-Reinforced Polymer (FRP) Bars now designated PRC-440.1-15 by ACI; the mandatory code for GFRP reinforcement is ACI CODE-440.11-22American Concrete Institute, USA, 2015Publisher (ACI) — purchase
SP 295.1325800.2017Concrete structures reinforced with fibre-reinforced polymer bars. Design rulesMinistry of Construction of the Russian Federation, 2018Official text (FAU FCS) — free
SP 405.1325800.2018Concrete structures with non-metallic fibres and polymer reinforcement. Design rulesMinistry of Construction of the Russian Federation, 2019Official text (FAU FCS) — free
SP 164.1325800.2014Strengthening of reinforced concrete structures with composite materials. Design rulesMinistry of Construction of the Russian Federation, 2015Official text (FAU FCS) — free
CNR-DT 203/2006Guide for the Design and Construction of Concrete Structures Reinforced with Fiber-Reinforced Polymer BarsNational Research Council (CNR), Italy, 2007Publisher (CNR) — free for personal use
ISIS Canada, Design Manual No. 3Reinforcing Concrete Structures with Fibre Reinforced Polymers — Design Manual No. 3ISIS Canada Research Network, 2007The ISIS Canada network has closed — no official source online
DSTU-N B V.2.6-185:2012Guidance on the design and construction of concrete structures with non-metallic composite reinforcement based on basalt and glass rovingMinistry of Regional Development of Ukraine, 2012Budstandart catalogue — subscription
TR 013-1-04Technical recommendations for the use of non-metallic composite reinforcement with a periodic profile in concrete structuresNIIZhB, Moscow, 2004Older recommendation — the current rules are in SP 295.1325800.2017
R-16-78Recommendations for the design of structures with fibreglass reinforcementNIIZhB, Moscow, 1978Older recommendation — the current rules are in SP 295.1325800.2017

Mesh and ties

Standards for composite mesh and ties
DesignationTitlePublisherSource
GOST 35315-2025Fibre-reinforced polymer mesh for reinforcing masonry walls. Specifications replaced GOST R 58964-2020Interstate standard, 2025Publisher (RST) — purchase
GOST 35300-2025Alkali-resistant glass-fibre reinforcing mesh for facades. Specifications replaced GOST R 55225-2017Interstate standard, 2025Publisher (RST) — purchase
GOST R 54923-2012Composite flexible ties for multi-layer enclosing structures. SpecificationsRosstandart, Russia, 2014Publisher (RST) — purchase

Standards and guides are copyright works of their publishers, so we don't publish copies — the link leads to the publisher or the official register, and where the publisher provides the text free of charge, it opens directly. These are not certificates for our rebar: the test reports above speak for it. We send the data a structural engineer needs on request.

Research from Montenegro

Continuous beams with GFRP reinforcement

At the Faculty of Civil Engineering of the University of Montenegro in Podgorica, seven continuous beams over two spans of 1,850 mm, with a 150 × 250 mm cross-section, were tested — six with glass-fibre-reinforced polymer (GFRP) bars and one with steel, for comparison.

The results show that moment redistribution in beams with GFRP reinforcement is possible without a loss of load-bearing capacity, and that ACI 440.1R-15 predicts the failure load well. The current codes, however, underestimate deflection under higher loads — so the authors propose a modified model for calculating deflection.

N. Baša, M. Ulićević, R. Zejak: Experimental Research of Continuous Concrete Beams with GFRP Reinforcement, Advances in Civil Engineering, 2018, article 6532723. Open-access paper

The research was not carried out on our rebar — we cite it as independent local research into how GFRP reinforcement behaves in concrete.

Research paper · 2018 · 16 pages · CC BY licence

Continuous concrete beams with GFRP reinforcement

N. Baša, M. Ulićević, R. Zejak — Faculty of Civil Engineering, University of Montenegro. Published in Advances in Civil Engineering (doi:10.1155/2018/6532723) under a Creative Commons Attribution licence.

Download paper · 4.0 MB

For structural engineers

What to know when designing

  1. High strength, lower stiffness

    GFRP rebar of type ASK to GOST 31938-2022 has a tensile strength of at least 1,000 MPa, but a modulus of elasticity of at least 50 GPa — about four times lower than steel. That is why deflection and cracking often govern the dimensions.

  2. Elastic up to failure

    Composite does not yield like steel — it behaves linearly elastically up to failure, so the design codes require larger load-bearing reserves.

  3. Temperature

    The polymer matrix softens above the glass transition temperature (at least 90 °C under GOST 31938-2022), so the standard limits its use at elevated temperatures.

  4. Bending

    The bar cannot be permanently bent on site like steel — stirrups and bent elements have to be provided for in the design in advance.

Where composite brings the most benefit, and where it needs a calculation, is explained on the why composite and composite rebar for construction pages.

Need documentation for a project?