Report No. 136/2023 · April 2023 · 6 pages
Tensile strength test of composite rebar Ø8 mm
Institute of Materials and Structures, Faculty of Civil Engineering, University of Belgrade. Average 1,036.5 MPa, weight 0.080 kg/m.
Download report · 2.8 MBTest reports for our rebar from an accredited laboratory, the standards composite rebar is produced and tested to, and the guides it is designed to — for structural engineers, site supervisors and clients.
Tests
Our Ø8 and Ø10 rebar was tested by the Institute of Materials and Structures of the Faculty of Civil Engineering, University of Belgrade, in a laboratory accredited to ISO/IEC 17025.
| Diameter | Report | Three specimens | Average | Weight | GOST 31938-2012 |
|---|---|---|---|---|---|
| Ø8 mm | No. 136/2023 | 1,018.6 – 1,056.4 MPa | 1,036.5 MPa | 0.080 kg/m | requirement met |
| Ø10 mm | No. 137/2023 | 995.7 – 1,072.0 MPa | 1,022.0 MPa | 0.134 kg/m | requirement met |
Ribbed rebar of type ASK was tested to GOST 31938-2012, Annex B — axial tension, April 2023. Every specimen is above 800 MPa, as the standard requires, and the average is above 1,000 MPa. For comparison: the yield strength of B500 steel is 500 MPa.
Report No. 136/2023 · April 2023 · 6 pages
Institute of Materials and Structures, Faculty of Civil Engineering, University of Belgrade. Average 1,036.5 MPa, weight 0.080 kg/m.
Download report · 2.8 MBReport No. 137/2023 · April 2023 · 6 pages
Institute of Materials and Structures, Faculty of Civil Engineering, University of Belgrade. Average 1,022.0 MPa, weight 0.134 kg/m.
Download report · 2.8 MBStandards and codes
As well as the GOST standards our rebar was tested to, structural engineers use the American guide ACI 440.1R and the national guides of other countries. Each one links to its publisher or the official register.
| Designation | Title | Publisher | Source |
|---|---|---|---|
| GOST 31938-2022 | Fibre-reinforced polymer bars for concrete reinforcement. General specifications types, requirements and designation of bars — our rebar was tested to the 2012 edition | Interstate standard, 2022 | Publisher (RST) — purchase |
| GOST 32492-2024 | … Methods for determining physical and mechanical properties replaced GOST 32492-2015 | Interstate standard, 2024 | Publisher (RST) — purchase |
| GOST 32486-2021 | … Methods for determining structural characteristics replaced GOST 32486-2015 | Interstate standard, 2021 | Publisher (RST) — purchase |
| GOST 32487-2015 | … Methods for determining resistance to aggressive media | Interstate standard, 2016 edition | Publisher (RST) — purchase |
| Designation | Title | Publisher | Source |
|---|---|---|---|
| ACI 440.1R-15 | Guide for the Design and Construction of Structural Concrete Reinforced with Fiber-Reinforced Polymer (FRP) Bars now designated PRC-440.1-15 by ACI; the mandatory code for GFRP reinforcement is ACI CODE-440.11-22 | American Concrete Institute, USA, 2015 | Publisher (ACI) — purchase |
| SP 295.1325800.2017 | Concrete structures reinforced with fibre-reinforced polymer bars. Design rules | Ministry of Construction of the Russian Federation, 2018 | Official text (FAU FCS) — free |
| SP 405.1325800.2018 | Concrete structures with non-metallic fibres and polymer reinforcement. Design rules | Ministry of Construction of the Russian Federation, 2019 | Official text (FAU FCS) — free |
| SP 164.1325800.2014 | Strengthening of reinforced concrete structures with composite materials. Design rules | Ministry of Construction of the Russian Federation, 2015 | Official text (FAU FCS) — free |
| CNR-DT 203/2006 | Guide for the Design and Construction of Concrete Structures Reinforced with Fiber-Reinforced Polymer Bars | National Research Council (CNR), Italy, 2007 | Publisher (CNR) — free for personal use |
| ISIS Canada, Design Manual No. 3 | Reinforcing Concrete Structures with Fibre Reinforced Polymers — Design Manual No. 3 | ISIS Canada Research Network, 2007 | The ISIS Canada network has closed — no official source online |
| DSTU-N B V.2.6-185:2012 | Guidance on the design and construction of concrete structures with non-metallic composite reinforcement based on basalt and glass roving | Ministry of Regional Development of Ukraine, 2012 | Budstandart catalogue — subscription |
| TR 013-1-04 | Technical recommendations for the use of non-metallic composite reinforcement with a periodic profile in concrete structures | NIIZhB, Moscow, 2004 | Older recommendation — the current rules are in SP 295.1325800.2017 |
| R-16-78 | Recommendations for the design of structures with fibreglass reinforcement | NIIZhB, Moscow, 1978 | Older recommendation — the current rules are in SP 295.1325800.2017 |
| Designation | Title | Publisher | Source |
|---|---|---|---|
| GOST 35315-2025 | Fibre-reinforced polymer mesh for reinforcing masonry walls. Specifications replaced GOST R 58964-2020 | Interstate standard, 2025 | Publisher (RST) — purchase |
| GOST 35300-2025 | Alkali-resistant glass-fibre reinforcing mesh for facades. Specifications replaced GOST R 55225-2017 | Interstate standard, 2025 | Publisher (RST) — purchase |
| GOST R 54923-2012 | Composite flexible ties for multi-layer enclosing structures. Specifications | Rosstandart, Russia, 2014 | Publisher (RST) — purchase |
Standards and guides are copyright works of their publishers, so we don't publish copies — the link leads to the publisher or the official register, and where the publisher provides the text free of charge, it opens directly. These are not certificates for our rebar: the test reports above speak for it. We send the data a structural engineer needs on request.
Research from Montenegro
At the Faculty of Civil Engineering of the University of Montenegro in Podgorica, seven continuous beams over two spans of 1,850 mm, with a 150 × 250 mm cross-section, were tested — six with glass-fibre-reinforced polymer (GFRP) bars and one with steel, for comparison.
The results show that moment redistribution in beams with GFRP reinforcement is possible without a loss of load-bearing capacity, and that ACI 440.1R-15 predicts the failure load well. The current codes, however, underestimate deflection under higher loads — so the authors propose a modified model for calculating deflection.
N. Baša, M. Ulićević, R. Zejak: Experimental Research of Continuous Concrete Beams with GFRP Reinforcement, Advances in Civil Engineering, 2018, article 6532723. Open-access paper
The research was not carried out on our rebar — we cite it as independent local research into how GFRP reinforcement behaves in concrete.
Research paper · 2018 · 16 pages · CC BY licence
N. Baša, M. Ulićević, R. Zejak — Faculty of Civil Engineering, University of Montenegro. Published in Advances in Civil Engineering (doi:10.1155/2018/6532723) under a Creative Commons Attribution licence.
Download paper · 4.0 MBFor structural engineers
GFRP rebar of type ASK to GOST 31938-2022 has a tensile strength of at least 1,000 MPa, but a modulus of elasticity of at least 50 GPa — about four times lower than steel. That is why deflection and cracking often govern the dimensions.
Composite does not yield like steel — it behaves linearly elastically up to failure, so the design codes require larger load-bearing reserves.
The polymer matrix softens above the glass transition temperature (at least 90 °C under GOST 31938-2022), so the standard limits its use at elevated temperatures.
The bar cannot be permanently bent on site like steel — stirrups and bent elements have to be provided for in the design in advance.
Where composite brings the most benefit, and where it needs a calculation, is explained on the why composite and composite rebar for construction pages.
Send us the diameters and quantities you are planning — we'll send the reports, rebar data and a quote.